Meta Pixel Saltar al contenido
Logo Geedle
Free demo · Fire brigades

Fire extinguisher and evacuation simulator: practice the small fire and the exit without risk

A 360° fire extinguisher simulator that runs in your browser: a bin is burning in the plant corridor and you raise the alarm, decide whether to fight the fire, apply the PASS technique (pull, aim, squeeze, sweep) and evacuate by the signed route to the assembly point, without the elevator. This is how fire brigades and all staff train before the drill.

Fire extinguisher and evacuation simulation with route map
Live demo

Try it: put out a small fire and evacuate to the assembly point

Two 360° scenes (plant corridor and assembly point), nine steps, three decisions and the extinguisher sweep mechanic.

  • Manual alarm before fighting the fire
  • Decision: fight the fire or evacuate?
  • PASS technique with a 4-second discharge button
  • Elevator, signed route, assembly point and roll call
Open full page →
Fire extinguisher and evacuation simulation with route map

What is a fire extinguisher and evacuation simulator?

It is an interactive scenario where a person practices the response to a small fire: raise the alarm, size up whether the fire can be fought, use the extinguisher with the PASS technique (pull the pin, aim at the base, squeeze the lever, sweep side to side) and evacuate by the right route to the assembly point. In our 360° version the fire is in a photographed corridor with an extinguisher, an alarm, an evacuation map and an elevator, and every decision gets immediate feedback. It does not replace live-fire practice for the brigade, but it prepares the whole staff so the drill and the live practice are shorter and more effective.

What the learner practices in this simulator

From the small fire to the assembly point, in the order emergency protocols set.

  • Raise the alarm first

    Manual pull station before any other action: the most common mistake is fighting the fire without warning anyone.

  • Size up the fire

    Size, smoke, right extinguisher and clear exit. If any is missing, evacuate.

  • PASS technique

    Pull the pin, aim at the base, squeeze and sweep. The discharge button requires holding for 4 seconds.

  • Evacuation map

    Locate the route, exits, extinguishers and assembly point on the wall map.

  • Elevator and route

    The elevator decision and leaving by the signed route, walking and closing doors.

  • Assembly point and roll call

    Stand in the marked area and report missing people without re-entering.

01

Why practice extinguisher use with a simulator?

Because in most companies only the brigade practices with live fire once a year, and the rest of the staff has never held an extinguisher. When a small fire starts, the closest person is usually not a brigade member. The simulator teaches that person the essentials: warn, size up, PASS with the exit at their back and retreat if the fire grows. And it gives the brigade a refresher of the full sequence (including roll call and the no-re-entry decision) as often as they want, with evidence per person for the emergency plan.

02

Which standards does the simulator consider?

The sequence follows Mexico's NOM-002-STPS-2010 (fire prevention and protection: brigades, drills, extinguishers) and NOM-026-STPS-2008 signage (evacuation routes, emergency exits and assembly point), consistent with NFPA 10 and OSHA 1910.157 practices. Texts adapt to your emergency plan, your extinguisher types (ABC, CO2, water) and your real routes.

03

How do we adapt the simulator to your plant?

We photograph your corridors, risk areas, exits and assembly points in 360°; place your real extinguishers and alarms as points of interest; and add the scenarios you need: electrical fire, gas leak, earthquake. Delivered as a SCORM or xAPI package for your LMS and as evidence for your emergency plan and drills.

What the simulator records for each person

Evidence for the emergency plan and for your LMS.

1

Alarm before attack

Whether they pulled the alarm before grabbing the extinguisher or skipped it.

2

Small-fire decision

Whether they correctly sized up size, smoke, extinguisher and exit.

3

PASS technique

Whether they grabbed the extinguisher, pulled the pin and completed the discharge on the base of the fire.

4

Elevator decision

Whether they used or rejected the elevator to evacuate.

5

Route and assembly point

Whether they left by the signed exit and reached the assembly point.

6

Roll call

What they did about a missing coworker: report or re-enter.

Want this simulator with your plant, your routes and your extinguishers?

Quote the scenario with your areas photographed in 360°. Three scope options with a closed price.

Traditional drill and practice vs. simulator

The simulator does not replace the drill: it makes sure people arrive knowing what to do.

Traditional practiceWith Geedle simulator
Who practices with an extinguisherOnly the brigade, once a yearAll staff, as often as needed; the brigade with live fire
Evacuation sequenceOne drill a yearIndividual refresher before every drill
Critical decisionsDiscussed in the talkMade and evaluated: small fire, theevator, re-entry
EvidenceAttendance list and drill reportSequence, decisions, errors and time per person (SCORM/xAPI)
New staffWaits for the next drillPractices it during onboarding, on day one
Process

How we build your custom simulator

Five phases with a deliverable you approve in each one.

  1. On-site survey

    360° photos and video of the area, the current procedure and an interview with the expert.

    Deliverable: technical script
  2. Instructional design

    Target behavior, critical decisions, frequent mistakes and the feedback for each one.

    Deliverable: storyboard and decision tree
  3. 360° scenario or 3D model

    Panoramas with hotspots, or the machine modeled when its movement must be simulated.

    Deliverable: navigable scenario
  4. Logic, rules and measurement

    Steps, interlocks, checklist, score and the xAPI events that will reach your LMS.

    Deliverable: working simulator
  5. Packaging and pilot

    SCORM or xAPI tested on your platform and a pilot with real staff before launch.

    Deliverable: published package and report
FAQ

Frequently asked questions about the extinguisher and evacuation simulator

Make sure your whole staff can use an extinguisher and evacuate

Tell us how many people, which areas and when your next drill is. We reply the same day.